Choose by the way the product needs to sit in the tray
Shortlist vacuum skin packaging when the product should stay in place and show clearly through a conforming film. Shortlist modified atmosphere packaging (MAP) when the product needs clearance under the lid or the pack specification requires a controlled gas atmosphere around it. Ask suppliers to trial the most difficult product shape in each proposed format before comparing machine speeds.
Vacuum skin packaging draws a heated, conformable film around the product and bonds it to a compatible tray or base in exposed areas. In a typical gas-flushed MAP tray, a lidding film seals around the flange after the machine replaces the air with the specified atmosphere. The package retains space between the lid and the product. Film, tray, tooling and process recipe are part of both decisions.
Use the required distribution orientation, peel performance and shelf-life specification as inputs. Have the quality team validate food safety and shelf life for the actual product, pack and cold chain. A successful machinery trial gives evidence about the sealing process and output.
Compare the pack and the installed equipment
| Decision | Vacuum skin | Gas-flushed MAP |
|---|---|---|
| Product geometry | Trial the tallest product and sharpest transitions for bridging or punctures. | Confirm clearance under the lid throughout handling and distribution. |
| Tray and film | Qualify the skin film against the tray or base and check seal appearance around the product. | Qualify lidding film, tray flange and barrier requirements for the gas and shelf-life specification. |
| Utilities and tooling | Confirm vacuum, film heating and tooling for each tray and product height. | Confirm gas supply and mixing scope, flush or vacuum-gas sequence, and headspace checks. |
| Production controls | Inspect film conformity, punctures, contamination and integrity. | Measure headspace composition where specified and verify seal integrity separately. |
MULTIVAC documents skin and modified-atmosphere applications. ULMA announced a new skin traysealer platform on 4 November 2026, illustrating why quoted cycle rates should be tied to a specific mode and tooling. Ask each supplier which modes and cavity counts are included in its proposal. A common platform can still require different tools, films and setup checks. Use the packaging material trial guide when changing the substrate or sealing layer.
Compare accepted trays per elapsed hour
Multiply cycles by active cavities only to calculate theoretical output. For the purchase comparison, count trays that meet the agreed specification at the inspection or discharge point and divide by elapsed trial time. Track seal defects, film faults, incomplete loads and downstream blocks as separate causes, with each rejected tray counted once.
In an illustrative one-hour trial, a four-cavity tool completes 700 cycles. It has 2,800 cavity opportunities. If 100 cavities go unfilled and 80 filled trays fail inspection, 2,620 trays pass. A line that needs 2,700 acceptable trays per hour is 80 short during that window. Compare suppliers with equivalent product loads and include normal interruptions. Report startup and changeover losses separately if those events are outside the measured window.
Compare annualized installed cost per accepted tray using the qualified rates and real SKU mix. Include film, trays, MAP gas where used, tooling, maintenance, cleaning, scrap, inspection and labor. Use the automation ROI guide to tie throughput benefits to actual capacity or labor changes.
Run four acceptance tests with production materials
- Challenge product geometry and material variation. Run the tallest skin product and the MAP format with the tightest lid clearance. Include production lots of trays and film, realistic fill placement and product temperature. Inspect the finished pack after normal conveying and handling.
- Test integrity and headspace separately. Agree peel or seal-strength criteria where required and select a suitable package leak test with the quality team. For MAP, define which gases to measure, when to sample and the limits to apply for that SKU. Record results by cavity to expose repeatable tooling faults.
- Prove the complete changeover and restart. Time from the last accepted tray to sustained acceptable output. Include tooling, film and recipe changes and first-off checks. Confirm how held trays and startup rejects are identified after an approved stop.
- Test at the installed line interfaces. Use realistic tray loading and discharge conditions. Confirm what happens if the filler starves or downstream inspection blocks, and identify who owns trial performance at each handoff. Review the line integration guide before freezing the purchase specification.
Key takeaways
- Start with product clearance, presentation and the required pack atmosphere.
- Check seal integrity separately from MAP headspace composition.
- Compare accepted trays per elapsed hour with production materials and realistic stops.
Frequently asked questions
What is the difference between vacuum skin packaging and MAP?
Vacuum skin packaging draws a conformable film closely around the product and seals it to a compatible support. Modified atmosphere packaging replaces air with a specified gas mixture and commonly retains headspace below a lidding film.
Can one traysealer run both vacuum skin and MAP?
Some platforms offer both modes. Check the exact machine, tooling, film feed and gas equipment in the quote, and ask the supplier to demonstrate the full changeover with your materials.
Does a good MAP headspace reading prove the tray is leak-free?
No. A headspace reading measures the gas composition in the sampled pack at the time of testing. Use a separate integrity test suitable for the pack and the leak sizes your quality team needs to detect.
Sources & editorial method
Source-checked 16 November 2026. Uses the linked manufacturer announcements and public technical documentation. The supplier examples describe available configurations. The trial design is PackLine IQ editorial analysis.