How induction cap sealing works
Induction cap sealing uses a magnetic field to heat the foil liner inside a capped bottle. The liner’s sealing layer bonds to the container rim when the materials, contact pressure and heating conditions are suitable. The sealing head stays above or around the moving closure. The cap holds the liner against the rim during heating.
Start with the complete package: container resin or glass finish, rim dimensions, liner construction, closure and application torque. Confirm compatibility with the liner and closure suppliers using filled packs. A nominally identical cap diameter can conceal a different foil position or rim geometry. Specify the capper as part of the filling and closing line because torque variation upstream changes what the sealer receives.
Fixed versus adaptive head-to-foil gap
The gap is measured to the foil itself. A tall closure can place the foil farther below the top of the cap than a shallow closure does. Enercon’s setup guidance describes how alignment, distance and conveyor speed influence the energy delivered. Faster travel reduces exposure time for a given head and setting.
| Option | When to evaluate it | Evidence to request |
|---|---|---|
| Fixed gap and power by recipe | Format geometry is stable and operators can reliably set the head after changeovers. | Documented head position and passing seals at the agreed limits of gap, speed and torque. |
| Gap-based power compensation | Measured gap variation consumes the available seal window and is difficult to remove mechanically. | Actual sensor reading, power response, qualified gap bounds and the response outside those bounds. |
| Different coil geometry | Deep or unusual closures put the foil in a difficult position relative to a flat head. | A trial of the offered head across the actual closure matrix, including clearances and change parts. |
Packaging World published Enercon’s supplier announcement about the Adaptive Sealing GAP system on 29 October 2026. Enercon describes recipe-based power adjustment from measured gap and an alert with optional rejection outside the programmed range. Confirm what is included in the quote and whether speed compensation is available separately. Head-to-foil distance and liner-to-rim contact are two different measurements.
Diagnose the seal pattern before changing power
Selig’s liner troubleshooting guide lists several possible causes of poor seals, including low application torque and product touching the liner. Treat these patterns as starting points for investigation.
- Weak bond around the whole rim. Verify the liner-to-container match, head alignment, power and actual conveyor speed. Inspect the filled pack for product at the sealing surface.
- One weak arc around the rim. Compare the defect orientation with the seam or a mark on the bottle. Inspect cap tilt, liner seating and rim flatness. Look for recurring defects by capper head or container lot if traceability allows.
- Burnt, wrinkled or distorted foil. Check for too much energy, a reduced gap or bottles slowing under the head. Record whether the defect clusters around a stop or restart.
Keep accepted and failed samples keyed to the format, component lots, torque, speed and head setup. Change one suspected cause at a time in a controlled trial so the team can tell which adjustment mattered.
Four tests to put in the purchase specification
- Map the operating window. Agree the filled formats, credible component tolerances, speed range and torque range. Test representative combinations at the edges of the proposed window. Record actual settings and quality results. Have plant quality define the sample size and release criteria.
- Challenge stops and format changes. Demonstrate restart after a normal stop and after a downstream backup. Identify every bottle exposed during a transition and demonstrate its agreed disposition. Change from the shortest to the tallest approved format and verify the selected recipe.
- Separate sensing from physical rejection. Use supplier-approved missing-foil and out-of-gap challenges where these functions are supplied. Follow marked bottles through the reject point. Test the agreed response when reject confirmation is lost. Review reject tracking and fault handling for comparable control checks.
- Verify finished-pack integrity. After agreed conditioning, apply the approved seal and leak-test methods to retained samples. Record visual adhesion and leakage separately. Include a repeat run with a different approved component lot if lot variation is a concern.
What to compare in supplier quotes
Compare the installed head, generator, mounting and height adjustment, bottle guides, recipe controls, liner sensing, reject hardware, guarding and commissioning. Ask who owns capper-to-sealer integration, retained sample testing and support when the line changes format. Include new format parts, maintenance and training in the cost comparison.
Compare good bottles released over the same scheduled duty, including setup, rework and restart losses. The automation payback guide can help value measured improvements without counting the same recovered output twice. The purchasing decision should turn on the qualified format range, verified seal integrity and reliable handling of suspect bottles.
Key takeaways
- Qualify each bottle, cap and liner combination.
- Measure the gap to the foil.
- Test the finished seal and the physical reject path separately.
Frequently asked questions
Why does an induction liner seal on only one side?
Check whether the cap is tilted, the rim is uneven, the liner is seated flat and the bottle runs through the center of the sealing head. Inspect the physical contact before raising power.
Can adaptive gap compensation fix a loose cap?
It adjusts heating for the measured head-to-foil distance within a qualified range. A loose or crooked cap can still prevent the liner from contacting the rim evenly.
Does a foil-presence sensor verify the seal?
It checks for the liner. Use a separate, validated check for the finished seal, and verify that challenged bottles are physically diverted when the line commands a reject.
How much does an installed induction cap sealer cost?
Comparable installed prices were not independently verified. Quote the head, controls, handling, format parts, inspection, reject hardware and qualification for the same line duty.
Sources & editorial method
Source-checked 4 November 2026. Uses the linked manufacturer announcements and public technical documentation. Supplier claims are attributed; no independent product benchmark is claimed. The comparison questions, procurement framework and acceptance trials are original editorial synthesis, not a certification protocol. No paid SEO tools were used.